Review




Structured Review

Boston Scientific Corporation jagwire revolution guidewire
Jagwire Revolution Guidewire, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/guidewire+jagwire/guidewire+high+jagwire+performance/pm42264229-25-12-37
Average 86 stars, based on 1 article reviews
jagwire revolution guidewire - by Bioz Stars, 2026-09
86/100 stars

Images

Related Articles

Migration:

Article Title: Digital single-operator cholangioscopy for difficult anastomotic biliary strictures in living donor liver transplant recipients after failure of standard ERCP: SPYPASS-2 study (with videos).
Article Snippet: Background and Aims: Liver transplantation (LT) is a curative treatment for end-stage liver disease.. Anastomotic biliary strictures (ABSs) are more common in living donor LT (LDLT).. However, the success rate of ERCP for ABS remains unsatisfactory.

Article Title: Endoscope traction technique to facilitate over-the-wire biliary cannulation during EUS-guided rendezvous
Article Snippet: A 0.035-inch × 450-cm straight-tip guidewire (Jagwire; Boston Scientific) was inserted into the biliary system through the needle and manipulated into the duodenum via the ampulla ( ).

Article Title: Successful reverse cannulation and needle-knife papillotomy of the minor papilla for accessory pancreatic duct cannulation
Article Snippet: Then, the guidewire intubated the minor papilla along the incision in the accessory pancreatic duct (APD; 450 cm, Jagwire; Boston Scientific Corp., Marlborough, Massachusetts, USA; c, d ).

Article Title: Reverse cannulation and dilation successfully assist the cannulation of the accessory pancreatic duct
Article Snippet: A new guidewire (450 cm, Jagwire; Boston Scientific Corp., Marlborough, Massachusetts, USA) was then placed in the APD.

Article Title: Successful reverse cannulation and needle-knife papillotomy of the minor papilla for accessory pancreatic duct cannulation
Article Snippet: Eventually, the guidewire (450 cm, Jagwire; Boston Scientific Corp., Marlborough, Massachusetts, USA) in the MPD successfully passed through the minor papilla and coiled in the duodenal lumen ( a, b ).

Article Title: Effect of duodenal papilla morphology on biliary cannulation and complications in patients with common bile duct stones.
Article Snippet: Background: The endoscopic appearance of the major duodenal papilla influences biliary cannulation and complications.. This study aimed to investigate the role of major duodenal papillae in the endoscopic treatment of common bile duct (CBD) stones.. Methods: This retrospective study was conducted at Bishan Hospital of Chongqing Medical University between January 2018 and August 2022.

Article Title: Managing dysfunctions and reinterventions in endoscopic ultrasound‐guided choledochoduodenostomy with lumen apposing metal stents: Illustrated technical review (with videos)
Article Snippet: Patient 6 – Video , 6 , 5 , 5 , D3 , 148 , Therapeutic gastroscope , Extractor balloon (Extractor Pro, Boston Scientific), guidewire (Jagwire, Boston Scientific), sphincterotome (AUTOtome, Boston Scientific), PC‐SEMS (Wallflex, Boston Scientific).

Article Title: Managing dysfunctions and reinterventions in endoscopic ultrasound‐guided choledochoduodenostomy with lumen apposing metal stents: Illustrated technical review (with videos)
Article Snippet: Patient 7 – described elsewhere , 6 , 273 , 2a–4 , E , 264 , Duodenoscope, linear echoendoscope , Extractor balloon (Extractor Pro, Boston Scientific), guidewire (Jagwire, Boston Scientific), sphincterotome (AUTOtome, Boston Scientific), LAMS (Hot Axios, Boston Scientific).

Saline:

Article Title: Digital single-operator cholangioscopy for difficult anastomotic biliary strictures in living donor liver transplant recipients after failure of standard ERCP: SPYPASS-2 study (with videos).
Article Snippet: Background and Aims: Liver transplantation (LT) is a curative treatment for end-stage liver disease.. Anastomotic biliary strictures (ABSs) are more common in living donor LT (LDLT).. However, the success rate of ERCP for ABS remains unsatisfactory.

Article Title: Endoscope traction technique to facilitate over-the-wire biliary cannulation during EUS-guided rendezvous
Article Snippet: A 0.035-inch × 450-cm straight-tip guidewire (Jagwire; Boston Scientific) was inserted into the biliary system through the needle and manipulated into the duodenum via the ampulla ( ).

Article Title: Successful reverse cannulation and needle-knife papillotomy of the minor papilla for accessory pancreatic duct cannulation
Article Snippet: Then, the guidewire intubated the minor papilla along the incision in the accessory pancreatic duct (APD; 450 cm, Jagwire; Boston Scientific Corp., Marlborough, Massachusetts, USA; c, d ).

Article Title: Reverse cannulation and dilation successfully assist the cannulation of the accessory pancreatic duct
Article Snippet: A new guidewire (450 cm, Jagwire; Boston Scientific Corp., Marlborough, Massachusetts, USA) was then placed in the APD.

Article Title: Successful reverse cannulation and needle-knife papillotomy of the minor papilla for accessory pancreatic duct cannulation
Article Snippet: Eventually, the guidewire (450 cm, Jagwire; Boston Scientific Corp., Marlborough, Massachusetts, USA) in the MPD successfully passed through the minor papilla and coiled in the duodenal lumen ( a, b ).

Article Title: Effect of duodenal papilla morphology on biliary cannulation and complications in patients with common bile duct stones.
Article Snippet: Background: The endoscopic appearance of the major duodenal papilla influences biliary cannulation and complications.. This study aimed to investigate the role of major duodenal papillae in the endoscopic treatment of common bile duct (CBD) stones.. Methods: This retrospective study was conducted at Bishan Hospital of Chongqing Medical University between January 2018 and August 2022.

Article Title: Managing dysfunctions and reinterventions in endoscopic ultrasound‐guided choledochoduodenostomy with lumen apposing metal stents: Illustrated technical review (with videos)
Article Snippet: Patient 6 – Video , 6 , 5 , 5 , D3 , 148 , Therapeutic gastroscope , Extractor balloon (Extractor Pro, Boston Scientific), guidewire (Jagwire, Boston Scientific), sphincterotome (AUTOtome, Boston Scientific), PC‐SEMS (Wallflex, Boston Scientific).

Article Title: Managing dysfunctions and reinterventions in endoscopic ultrasound‐guided choledochoduodenostomy with lumen apposing metal stents: Illustrated technical review (with videos)
Article Snippet: Patient 7 – described elsewhere , 6 , 273 , 2a–4 , E , 264 , Duodenoscope, linear echoendoscope , Extractor balloon (Extractor Pro, Boston Scientific), guidewire (Jagwire, Boston Scientific), sphincterotome (AUTOtome, Boston Scientific), LAMS (Hot Axios, Boston Scientific).



Similar Products

86
Boston Scientific Corporation jagwire revolution guidewire
Jagwire Revolution Guidewire, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/guidewire+jagwire/guidewire+high+jagwire+performance/pm42264229-25-12-37
Average 86 stars, based on 1 article reviews
jagwire revolution guidewire - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

86
Boston Scientific Corporation jagwire high performance guidewire
Cholangioscopy-assisted EUS-GE in a patient with surgically altered anatomy. The video highlights overcoming severe scope looping by cholangioscopy through a colonoscope, precise navigation using angled-tip guidewires under direct vision, establishment of dual-guidewire access for the procedural backup, and safe deployment of a LAMS with real-time confirmation, minimizing fluoroscopy use. Video 1
Jagwire High Performance Guidewire, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/guidewire+jagwire/guidewire+high+jagwire+performance/pmc12782816-8-4-2
Average 86 stars, based on 1 article reviews
jagwire high performance guidewire - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

90
Boston Scientific Corporation ercp guidewire jagwire
Loop-tipped <t>guidewire-assisted</t> cannulation of disposable imaging catheter into the appendiceal lumen. a Computed tomography showing dilated appendix (14 mm). b Loop-tipped guidewire modification. c Edematous appendiceal orifice on colonoscopy. d Successful catheter cannulation. e Endoscopic view of purulent debris. f Deployed single-pigtail stent.
Ercp Guidewire Jagwire, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/guidewire+jagwire/ercp+guidewire+jagwire/pmc12270651-7-1-5
Average 90 stars, based on 1 article reviews
ercp guidewire jagwire - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Boston Scientific Corporation jagwire pulmonary guidewire
Loop-tipped <t>guidewire-assisted</t> cannulation of disposable imaging catheter into the appendiceal lumen. a Computed tomography showing dilated appendix (14 mm). b Loop-tipped guidewire modification. c Edematous appendiceal orifice on colonoscopy. d Successful catheter cannulation. e Endoscopic view of purulent debris. f Deployed single-pigtail stent.
Jagwire Pulmonary Guidewire, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/guidewire+jagwire/guidewire+pulmonary+jagwire/pm40497639-41-24-9
Average 90 stars, based on 1 article reviews
jagwire pulmonary guidewire - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Boston Scientific Corporation guidewire jagwire
<t>Guidewire</t> and minor papilla sphincterotomy using the needle knife. a, b The guidewire in the MPD successfully passed through the minor papilla and coiled in the duodenal lumen. c, d Under the guidance of the guidewire, the approximate location of the minor papilla was found, and sphincterotomy was performed using the needle knife after pulling out the guidewire, and the guidewire intubated the minor papilla along the incision in the APD.
Guidewire Jagwire, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/guidewire+jagwire/guidewire+jagwire/pmc12040490-9-2-6
Average 90 stars, based on 1 article reviews
guidewire jagwire - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Boston Scientific Corporation guidewire for non-vascular use hydra jagwire, 0.035-inch
Endoscopic gallbladder stenting method. A catheter is inserted into the bile duct, and a <t>guidewire</t> is advanced into the gallbladder. The catheter is followed by the guidewire, and a stent is placed in the gallbladder after cholecystography is performed (cited from the Canadian Journal of Gastroenterology and Hepatology [15]).
Guidewire For Non Vascular Use Hydra Jagwire, 0.035 Inch, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/guidewire+jagwire/guidewire+for+non+vascular+use+hydra+jagwire++0+035+inch/pmc11670053-55-20-27
Average 90 stars, based on 1 article reviews
guidewire for non-vascular use hydra jagwire, 0.035-inch - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Boston Scientific Corporation 450 jagwire guidewire
Endoscopic gallbladder stenting method. A catheter is inserted into the bile duct, and a <t>guidewire</t> is advanced into the gallbladder. The catheter is followed by the guidewire, and a stent is placed in the gallbladder after cholecystography is performed (cited from the Canadian Journal of Gastroenterology and Hepatology [15]).
450 Jagwire Guidewire, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/guidewire+jagwire/0+035+inch+guidewire+jagwire/pmc11701448-118-18-21
Average 90 stars, based on 1 article reviews
450 jagwire guidewire - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Cholangioscopy-assisted EUS-GE in a patient with surgically altered anatomy. The video highlights overcoming severe scope looping by cholangioscopy through a colonoscope, precise navigation using angled-tip guidewires under direct vision, establishment of dual-guidewire access for the procedural backup, and safe deployment of a LAMS with real-time confirmation, minimizing fluoroscopy use. Video 1

Journal: Endoscopy

Article Title: Cholangioscopy and double guidewires facilitate a difficult endoscopic ultrasound-guided gastroenterostomy

doi: 10.1055/a-2743-2487

Figure Lengend Snippet: Cholangioscopy-assisted EUS-GE in a patient with surgically altered anatomy. The video highlights overcoming severe scope looping by cholangioscopy through a colonoscope, precise navigation using angled-tip guidewires under direct vision, establishment of dual-guidewire access for the procedural backup, and safe deployment of a LAMS with real-time confirmation, minimizing fluoroscopy use. Video 1

Article Snippet: Subsequently, a Boston Scientific Jagwire high-performance guidewire (M00556580) was inserted via an 8.5 Fr bougie catheter to secure dual-wire access ( ).

Techniques:

An angled-tip hydrophilic guidewire was inserted, navigating a sharply curved duodenal bulb with the maximal bend highlighted by a red circle, and advancing distally into the jejunum.

Journal: Endoscopy

Article Title: Cholangioscopy and double guidewires facilitate a difficult endoscopic ultrasound-guided gastroenterostomy

doi: 10.1055/a-2743-2487

Figure Lengend Snippet: An angled-tip hydrophilic guidewire was inserted, navigating a sharply curved duodenal bulb with the maximal bend highlighted by a red circle, and advancing distally into the jejunum.

Article Snippet: Subsequently, a Boston Scientific Jagwire high-performance guidewire (M00556580) was inserted via an 8.5 Fr bougie catheter to secure dual-wire access ( ).

Techniques:

A fluoroscopic image showing dual-guidewire access established using an 8.5 Fr bougie catheter.

Journal: Endoscopy

Article Title: Cholangioscopy and double guidewires facilitate a difficult endoscopic ultrasound-guided gastroenterostomy

doi: 10.1055/a-2743-2487

Figure Lengend Snippet: A fluoroscopic image showing dual-guidewire access established using an 8.5 Fr bougie catheter.

Article Snippet: Subsequently, a Boston Scientific Jagwire high-performance guidewire (M00556580) was inserted via an 8.5 Fr bougie catheter to secure dual-wire access ( ).

Techniques:

Successful deployment of a LAMS between the stomach and the jejunum under combined guidance of dual-guidewire access and cholangioscopy, with the LAMS position highlighted by a red circle. LAMS, lumen-apposing metal stent.

Journal: Endoscopy

Article Title: Cholangioscopy and double guidewires facilitate a difficult endoscopic ultrasound-guided gastroenterostomy

doi: 10.1055/a-2743-2487

Figure Lengend Snippet: Successful deployment of a LAMS between the stomach and the jejunum under combined guidance of dual-guidewire access and cholangioscopy, with the LAMS position highlighted by a red circle. LAMS, lumen-apposing metal stent.

Article Snippet: Subsequently, a Boston Scientific Jagwire high-performance guidewire (M00556580) was inserted via an 8.5 Fr bougie catheter to secure dual-wire access ( ).

Techniques:

Loop-tipped guidewire-assisted cannulation of disposable imaging catheter into the appendiceal lumen. a Computed tomography showing dilated appendix (14 mm). b Loop-tipped guidewire modification. c Edematous appendiceal orifice on colonoscopy. d Successful catheter cannulation. e Endoscopic view of purulent debris. f Deployed single-pigtail stent.

Journal: Endoscopy

Article Title: Loop-tipped guidewire-assisted cannulation of disposable imaging catheter into appendiceal lumen for difficult endoscopic retrograde appendicitis therapy

doi: 10.1055/a-2641-2086

Figure Lengend Snippet: Loop-tipped guidewire-assisted cannulation of disposable imaging catheter into the appendiceal lumen. a Computed tomography showing dilated appendix (14 mm). b Loop-tipped guidewire modification. c Edematous appendiceal orifice on colonoscopy. d Successful catheter cannulation. e Endoscopic view of purulent debris. f Deployed single-pigtail stent.

Article Snippet: A standard ERCP guidewire (Jagwire; Boston Scientific, Marlborough, Massachusetts, USA) was manually shaped to form a loop at its tip ( b ).

Techniques: Imaging, Computed Tomography, Modification

Guidewire and minor papilla sphincterotomy using the needle knife. a, b The guidewire in the MPD successfully passed through the minor papilla and coiled in the duodenal lumen. c, d Under the guidance of the guidewire, the approximate location of the minor papilla was found, and sphincterotomy was performed using the needle knife after pulling out the guidewire, and the guidewire intubated the minor papilla along the incision in the APD.

Journal: Endoscopy

Article Title: Successful reverse cannulation and needle-knife papillotomy of the minor papilla for accessory pancreatic duct cannulation

doi: 10.1055/a-2573-7409

Figure Lengend Snippet: Guidewire and minor papilla sphincterotomy using the needle knife. a, b The guidewire in the MPD successfully passed through the minor papilla and coiled in the duodenal lumen. c, d Under the guidance of the guidewire, the approximate location of the minor papilla was found, and sphincterotomy was performed using the needle knife after pulling out the guidewire, and the guidewire intubated the minor papilla along the incision in the APD.

Article Snippet: Eventually, the guidewire (450 cm, Jagwire; Boston Scientific Corp., Marlborough, Massachusetts, USA) in the MPD successfully passed through the minor papilla and coiled in the duodenal lumen ( a, b ).

Techniques:

Endoscopic gallbladder stenting method. A catheter is inserted into the bile duct, and a guidewire is advanced into the gallbladder. The catheter is followed by the guidewire, and a stent is placed in the gallbladder after cholecystography is performed (cited from the Canadian Journal of Gastroenterology and Hepatology [15]).

Journal: DEN Open

Article Title: Recurrence rate of cholecystitis after initial gallbladder stenting versus secondary gallbladder stenting: A propensity score matching study

doi: 10.1002/deo2.70047

Figure Lengend Snippet: Endoscopic gallbladder stenting method. A catheter is inserted into the bile duct, and a guidewire is advanced into the gallbladder. The catheter is followed by the guidewire, and a stent is placed in the gallbladder after cholecystography is performed (cited from the Canadian Journal of Gastroenterology and Hepatology [15]).

Article Snippet: Angiographic guidewire (Radifocus, 0.032‐inch [Terumo Corp.], disposable guidewire [VisiGlide 2, 0.025‐inch {Olympus}], endoscopic guidewire [VENTY, 0.025‐inch {Boston Scientific Corp.}], and guidewire for non‐vascular use [Hydra Jagwire, 0.035‐inch {Boston Scientific}]).

Techniques:

Fluoroscopic images. (a) Fluoroscopic image of gallbladder intubation. The guidewire is looped in the gallbladder. (b) Fluoroscopic image of a stent placed in the gallbladder.

Journal: DEN Open

Article Title: Recurrence rate of cholecystitis after initial gallbladder stenting versus secondary gallbladder stenting: A propensity score matching study

doi: 10.1002/deo2.70047

Figure Lengend Snippet: Fluoroscopic images. (a) Fluoroscopic image of gallbladder intubation. The guidewire is looped in the gallbladder. (b) Fluoroscopic image of a stent placed in the gallbladder.

Article Snippet: Angiographic guidewire (Radifocus, 0.032‐inch [Terumo Corp.], disposable guidewire [VisiGlide 2, 0.025‐inch {Olympus}], endoscopic guidewire [VENTY, 0.025‐inch {Boston Scientific Corp.}], and guidewire for non‐vascular use [Hydra Jagwire, 0.035‐inch {Boston Scientific}]).

Techniques: